1,0

Accuracy class:

60 A

Maximum current (Imax)

0.25 – 60 A

Set operating current range

10 mA

Starting current

30 years

Average service life

from - 30 to + 55 °C

Operating temperature range

It is designed for measuring and multi-tariff accounting of active alternating current electric energy in single-phase two-wire alternating current networks with a frequency of 50 Hz, both autonomously and as part of automated systems for monitoring and accounting of electric energy ASKUE-byt.

Peculiarities

Provides setting and polling via PLC communicator (NEW!!!) Complies with GOST 31818.11-2012, GOST 31819.21-2012 and technical requirements of Belenergo concern. The meter provides storage, setting and polling via RS-485 interface or PLC communicator and optical interface using a computer, interface converter and software of the following parameters.

Reliable Electricity Meter

Technical specifications

accuracy class

1,0

base current (Iб), A

5

maximum current (Imax), A

60

set operating current range, A

0,25-60

extended operating current range, A

0,1 - 60

rated voltage, V

220

set working voltage range, V

198 – 242

extended operating voltage range, V

154 – 264

maximum working voltage range, V

115-380

frequency change range, Hz

49-51

starting current, mA

10

meter constant, imp/kW h

5000

price of one digit of the counting mechanism, kW h junior, not less than

0,001

price of one digit of the counting mechanism, kW h senior, no more

100000

Power consumption, no more than in the voltage circuit: - full, V A

1,5

Power consumption, no more than in the voltage circuit: - active, W

0,75

in the current circuit: - total, V A

0,05

average service life, years

30

weight of the meter, kg, no more than

0.75

daily clock rate in NU, s, no more than

± 1

operating temperature range, °C

from - 30 to + 55

mean time to failure, hours

80 000

Additionally

Materials for download

Advantages:
- Maximum permissible input working voltage 115-380V
- 8-digit LCD indicator with enlarged digital characters.
- Built-in interface power supply

The meter provides the following settings:
- current amount of consumed electricity with a cumulative total separately by four tariffs and their sum;
- amount of consumed electricity with a cumulative total at the beginning of the current and 11 previous months separately by four tariffs and their sum;
- maximum half-hourly power, for the current and 11 previous months separately by 4 tariffs and their sum;
- maximum half-hourly power for the current and 60 previous days separately by 4 tariffs and total for the day;
load control output status;
- time, date and flag of the last 64 changes in meter parameters.
- current time and date;
- up to 48 tariff zones per day, with a switching resolution of 30 minutes;
-up to 15 daily profiles;
-up to 8 weekly profiles;
-power limit value;
-meter password;
-meter serial number.

If you have any questions about the purchase, please leave your contacts and we will call you back as soon as possible.

Contact us

      Send a request